1 - 6
1. FUNCTIONS AND CONFIGURATION
(2) Operation by external input signals and communication
(a) Definition
The data change and selection of point tables, change of parameters and confirmation of the monitor
can be performed through communication. The forward rotation start (ST1) or reverse rotation direction
(ST2) is input from the external I/O. This system is used when the position data and speed setting, the
parameter change and others are performed on a host personal computer, etc.
(b) Configuration
1) Connect a servo amplifier to a personal computer with USB.
MR-J3- T MR-J3-D01
CNP3
CN2
CN6
CN1
CN3
CN5
CN10
CN20
CN30
MR Configurator
USB
External I/O
signal
Personal
Computer
2) Connect two or more (maximum 32) servo amplifiers to a personal computer with RS-422.
MR-J3- T MR-J3-D01
CNP3
CN2
CN6
CN1
CN3
CN5
CN10
CN20
CN30
MR Configurator
RS-232C
MR-J3- T MR-J3-D01
CNP3
CN2
CN6
CN1
CN3
CN5
CN10
CN20
CN30
RS-422
RS-232C/RS-422 converter
(This should be
prepared by the customer.
)
External I/O
signal
External I/O
signal
To the next axis
Personal
Computer