Mitsubishi Electronics MR-J3-D01 Car Amplifier User Manual


 
4 - 16
4. OPERATION
Choose the servo motor rotation direction at the time when the forward rotation start (ST1) signal or
reverse rotation start (ST2) signal is switched on with parameter No.PA14 (Rotation direction
selection).
Parameter No.PA14 setting
Servo motor rotation direction
Forward rotation start (ST1) ON Reverse rotation start (ST2) ON
0 CCW rotation (address incremented) CW rotation (address decremented)
1 CW rotation (address incremented) CCW rotation (address decremented)
Parameter No.PA14: 0 Parameter No.PA14: 1
CW
ST2: ON
CW
ST1: ON
ST2: ON
CCW
ST1: ON
CCW
Set the unit multiplication factor (STM) of position data with parameter No.PA05 (Feed function
selection).
Parameter No.PA05 setting Feed unit [μm] Position data input range [mm]
0 1 0 to 999.999
1 10 0 to 9999.99
2 100 0 to 99999.9
3 1000 0 to 999999
3) Operation
Choosing the point table using DI0 to DI7 and turning ST1 ON starts a motion in the forward rotation
direction over the moving distance of the position data at the preset speed and acceleration time constant.
Turning ST2 ON starts a motion in the reverse rotation direction according to the values set to the selected
point table.
Item Setting method Description
Automatic operation mode
selection
Automatic/manual selection (MD0) Turn MD0 ON.
Point table selection
Point table No. selection 1 (DI0)
Point table No. selection 2 (DI1)
Point table No. selection 3 (DI2)
Point table No. selection 4 (DI3)
Point table No. selection 5 (DI4)
Point table No. selection 6 (DI5)
Point table No. selection 7 (DI6)
Point table No. selection 8 (DI7)
Refer to this text
Start
Forward rotation start (ST1)
Turn ST1 ON to start motion in forward
rotation direction.
Reverse rotation start (ST2)
Turn ST2 ON to start motion in reverse
rotation direction.