4.7.14 Automatic positioning function to the home position
POINT
You cannot perform automatic positioning from outside the position data
setting range to the home position. In this case, make a home position return
again using a manual home position return.
If this function is used when returning to the home position again after performing a manual home position
return after a power-on and deciding the home position, automatic positioning can be carried out to the home
position at high speed. In an absolute position system, manual home position return is not required after
power-on.
Please perform a manual home position return beforehand after a power-on.
Set the input signals and parameter as follows.
Item Device/Parameter used Description
Manual home position return mode
selection
Automatic/manual selection (MD0) Turn MD0 ON.
(Note)
Point table No. selection 1 to 8
(DI0 to DI7)
DI0 to DI7 are turned off.
Home position return speed Parameter No.PC04 Set the speed till the dog is detected.
Home position return
acceleration/deceleration time
constants
Point table No.1
Use the acceleration/deceleration time constant
of point table No. 1.
Note. This setting is for when the point table is used. When using the BCD input, turn SP0 to 3 OFF.
Set up the home position return speed of the automatic positioning function to the home position by parameter
No.PC04. Use the data of point table No.1 to set the acceleration time constant and deceleration time
constant. When reverse rotation start (ST2) is ON, it will position automatically at the home position.
ON
OFF
Acceleration time constant
of point table No. 1
Deceleration time constant
of point table No. 1
Home position
Servo motor speed
Forward rotation start (ST1)
Reverse rotation start (ST2)
Forward
rotation
0r/min
Home position return speed
Parameter No. PC04
ON
OFF