Mitsubishi Electronics MR-J3-D01 Car Amplifier User Manual


 
14 - 13
14. COMMUNICATION FUNCTION
(5) Current alarm (Command [0][2]
[3][5])
Command Data No. Description Frame Length
[0] [2] [0] [0] Current alarm number 4
[3] [5] [0][0] Status display name and unit at
alarm occurrence
Current position 16
[0][1] Command position
[0][2] Command remaining distance
[0][3] Point table No.
[0][4] Cumulative feedback pulses
[0][5] Servo motor speed
[0][6] Droop pulses
[0][7] Override voltage
[0][8] Override
[0][9] Analog torque limit voltage
[0][A] Regenerative load ratio
[0][B] Effective load ratio
[0][C] Peak load ratio
[0][D] Instantaneous torque
[0][E] Within one-revolution position
[0][F] ABS counter
[1][0] Load inertia moment ratio
[1][1] Bus voltage
[0][0] Status display data value and
processing information at alarm
occurrence
Current position 12
[0][1] Command position
[0][2] Command remaining distance
[0][3] Point table No.
[0][4] Cumulative feedback pulses
[0][5] Servo motor speed
[0][6] Droop pulses
[0][7] Override voltage
[0][8] Override
[0][9] Analog torque limit voltage
[0][A] Regenerative load ratio
[0][B] Effective load ratio
[0][C] Peak load ratio
[0][D] Instantaneous torque
[0][E] Within one-revolution position
[0][F] ABS counter
[1][0] Load inertia moment ratio
[1][1] Bus voltage
(6) Point table/position data (Command [4][0])
Command Data No. Description Frame length
[4][0] [0][1] to [F][F] Position data read
The decimal equivalent of the data No. value (hexadecimal) corresponds to the Point
table No.
8
(7) Point table/speed data (Command [5][0])
Command Data No. Description Frame length
[5][0] [0][1] to [F][F] Speed data read
The decimal equivalent of the data No. value (hexadecimal) corresponds to the Point
table No.