1. FUNCTIONS AND CONFIGURATION
1.6.3 Installation and removal of MR-J3-D01
WARNING
Before installing or removing the MR-J3-D01, turn off the power and wait for 15
minutes or more until the charge lamp turns off. Then, confirm that the voltage
between P(
) and N( ) is safe with a voltage tester and others. Otherwise, an
electric shock may occur. In addition, always confirm from the front of the servo
amplifier, whether the charge lamp is off or not.
CAUTION
Avoid installing and removing the MR-J3-D01 repeatedly. Any contact failure of the
connector may be caused.
Avoid unsealing the MR-J3-D01 to be free dust and dirt against the connector
except installing. Make sure to use the pre-packing when storing.
Avoid using the MR-J3-D01 which the hook and knobs for fixing are damaged. Any
contact failure of the connector may be caused.
When installing and removing the MR-J3-D01 to the MR-J3-500T or more, avoid
dropping out the installing screw inside it. Any malfunctions of the servo motor may
be caused.
When installing and removing the MR-J3-D01 to the MR-J3-500T or more, avoid
damaging the control board by the fixing plate. Any malfunctions of the servo motor
may be caused.
Make sure to tighten the MR-J3-D01 with the enclosed installing screws when
installing.
POINT
The internal circuits of the servo amplifier may be damaged by static
electricity.
Always take the following precautions.
Ground human body and work bench.
Do not touch the conductive areas, such as connector pins and electrical
parts, directly by hand.