5 - 9
5. OPERATION
(2) Indication list
Indication Status Description
b ##
Waiting for CC-Link
communication
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
(Note 1)
d ##
Ready
The servo was switched on after completion of initialization and the servo amplifier is ready
to operate. (This is indicated for 2 seconds.)
(Note 1)
C # #
Not ready The servo amplifier is being initialized or an alarm has occurred.
(Note 2)
$ $ $
Ready for operation
Two seconds have passed after the servo amplifier is ready to operate by turning ON the
servo-on (RYn1).
(Note 3)
A
Alarm
Warning The alarm No./warning No. that occurred is displayed. (Refer to section 11.4.)
8 88
CPU error CPU watchdog error has occurred.
(Note 4)
0 0.b
JOG operation
positioning operation programmed operation DO forced output single-
step feed
# #.d
(Note 1)
# #.C
(Note 4)
Test operation mode
Motor-less operation
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
## Description
00 Set to the test operation mode.
01 Station number 1
02 Station number 2
03 Station number 3
:
:
:
:
62 Station number 62
63 Station number 63
64 Station number 64
Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number.
3.
indicates the warning/alarm No.
4. Requires MR Configurator or MR-PRU03 parameter module.