Mitsubishi Electronics MR-J3 Car Amplifier User Manual


 
16 - 68
16. INDEXER POSITIONING OPERATION
(3) Structure
Component Description
Servo amplifier
Servo motor
Use standard models.
Battery MR-J3BAT
Encoder cable Use a standard model. (Refer to section 14.1.)
(4) Outline of absolute position detection data communication
For normal operation, as shown below, the encoder consists of a detector designed to detect a position
within one revolution and a cumulative revolution counter designed to detect the number of revolutions.
The absolute position detection system always detects the absolute position of the machine and keeps it
battery-backed, independently of whether the general-purpose programming controller power is on or off.
Therefore, once the home position is defined at the time of machine installation, home position return is not
needed when power is switched on thereafter.
If a power failure or a fault occurs, restoration is easy.
MR-J3BAT
LSO
1XO
I/O circuit
Position data, speed data
(current position read)
Home position return
data
EEP-ROM memory
Backup at
power off
LS
Speed detection
1X
Detection of position
within one revolution
Within one-revolution counter
High-speed serial
communication
Speed control
Position control
1 pulse/rev. Cumulative revolution counter
Point table No. selection,
etc.
Servo amplifier
Servo motor
Current position
(5) Battery installation procedure
WARNING
Before installing a battery, turn off the main circuit power while keeping the control
circuit power on. Wait for 15 minutes or more until the charge lamp turns off. Then,
confirm that the voltage between P(
) and N( ) is safe with a voltage tester and
others. Otherwise, an electric shock may occur. In addition, always confirm from
the front of the servo amplifier whether the charge lamp is off or not.
POINT
The internal circuits of the servo amplifier may be damaged by static electricity.
Always take the following precautions.
Ground human body and work bench.
Do not touch the conductive areas, such as connector pins and electrical
parts, directly by hand.
Before starting battery changing procedure, make sure that the main circuit
power is switched OFF with the control circuit power ON. When battery is