1 - 26
1. FUNCTIONS AND CONFIGURATION
1.7 Configuration including auxiliary equipment
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
(1) MR-J3-100T or less
(a) For 3-phase or 1-phase 200V to 230VAC
CN5
PC
CN6
CN2
CN4
I/O signal
U
V
W
CN3
L1
L
3
L
2
P
1
P2
CN1
CC-Link
Magnetic
contactor
(MC)
(Note 2)
Power factor
improving DC
reactor
(FR-BEL)
(Note 2)
Regenerative option
(Note 1)
Battery
MR-J3BAT
Servo motor
Personal
computer
MR Configurator
Line noise
filter
(FR-BSF01)
Servo amplifier
R S T
(Note 3)
Power supply
No-fuse breaker
(NFB) or fuse
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1 and P2.
3. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70T or less.
For 1-phase 200V to 230VAC, connect the power supply to L
1 L2 and leave L3 open. Refer to section 1.2 for the power supply
specification.