6 - 35
6. PARAMETERS
No. Symbol Name and function
Initial
value
Unit
Setting
range
PD14 DIN3 External DI function selection 3
This function sets any signal imported from the CN6 connector.
part is for manufacturer setting. Do not set the value by any means.
8
Initial value
BIN HEX
Device name
0
0
0
1
BIN 0: Used in CC-Link
BIN 1: Used in CN6 external input signal
Proximity dog (DOG)
0
Initial value
BIN HEX
Device name
0
Automatic/manual
selection (MD0)
0
0
0
0
0
Initial value
BIN HEX
Device name
0
Temporary
stop/Restart (TSTP)
0
0
0
0800h Refer to
name and
function
column.
PD15 For manufacturer setting
Do not change this value by any means.
0000h
PD16 *DIAB Input polarity selection
Used to set the proximity dog input polarity. (Refer to section 5.6.)
0
Proximity dog input polarity
0: OFF indicates detection of the dog
1: ON indicates detection of the dog
00
0000h Refer to
name and
function
column.
PD17 0000h
PD18
For manufacturer setting
Do not change this value by any means.
0000h
PD19 *DIF Response level setting
Used to select the input.
000
Input filter
If external input signal causes chattering due
to noise, etc., input filter is used to suppress it.
0: None
1: 0.88[ms]
2: 1.77[ms]
3: 2.66[ms]
4: 3.55[ms]
5: 4.44[ms]
0002h Refer to
name and
function
column.