App. 8.2.4 Program example when 2 stations are occupied
POINT
To execute a dog type home position return with the CC-Link communication
functions, set "
0 " in parameter No.PD14 and use Proximity dog (DOG)
with the remote input (RY03) in this example.
Operate the servo amplifier of station 1 in the positioning mode and read the "motor speed" data.
Preset the parameter No.PC30 to "
2".
Operation: Alarm reset, dog type home position return, JOG operation, automatic operation under point table
command
Code No. Description
H0016 32-bit data of motor speed (hexadecimal)
Code No. Description
K50000 Position command data (decimal)
K100 Speed command data (decimal)
Reads remote input (RX00 to RX3F) of buffer
memory to M200 to M263.
Check the status of CC-Link.
Reads RWr3 and RWr2 of buffer memory to
D11 and D12 when instruction code execution
completion (RX09) turns on.
Reset command
Servo-on command
Automatic/manual selection
Home position return
command
Home position return completion
Automatic/manual selection
Automatic operation mode selection (RY06)
Manual operation mode selection (RY06)
Home position return request
Forward rotation start request
Forward rotation start request reset
Proximity dog command (RY03)
Command request time 10ms *1
Point table establishment time 10ms *1
Writes current alarm read (H0010) to RWw2 at
trouble (RX3A) occurrence.
Turns on instruction code execution demand
(RY09).
Turns off instruction code execution demand
(RY09).
Alarm reset command (RY3A)
Servo-on command (RY00)
Proximity dog command