1 - 6
1. FUNCTIONS AND CONFIGURATION
(2) Operation using CC-Link communication functions and external input signals
(a) Operation
Using parameter No.PD06 to PD08 and parameter No.PD12, PD14, input devices can be assigned to
the external input devices of CN1A and CN1B. The signals assigned to the external input signals cannot
be used with the CC-Link communication functions. Output devices can be used with the CN6
connectors and CC-Link communication functions simultaneously.
(b) Configuration
CN2
CN6
CN1
CNP3 CNP3
CN2
CN6
CN1
External I/O
signal
External I/O
signal
Servo amplifier
(Axis 1)
Servo amplifier
(Axis 2)
To the next axis
Programmable controller
CC-Link master unit