Appendix AAbbreviated Register Listing 63230-300-212
Register Listing April 2001
© 2001 Schneider Electric All Rights Reserved
156
2620 to 2639
Generic Channel #12
Same as registers 2400 to 2419 except for Channel #12
2640 to 2659
Generic Channel #13
Same as registers 2400 to 2419 except for Channel #13
2660 to 2679
Generic Channel #14
Same as registers 2400 to 2419 except for Channel #14
2680 to 2699
Generic Channel #15
Same as registers 2400 to 2419 except for Channel #15
2700 to 2719
Generic Channel #16
Same as registers 2400 to 2419 except for Channel #16
2720 to 2739
Generic Channel #17
Same as registers 2400 to 2419 except for Channel #17
2740 to 2759
Generic Channel #18
Same as registers 2400 to 2419 except for Channel #18
2760 to 2779
Generic Channel #19
Same as registers 2400 to 2419 except for Channel #19
2780 to 2799
Generic Channel #20
Same as registers 2400 to 2419 except for Channel #20
Phase Extremes
2800 Current, Highest Phase Value A Amps/Scale 0 to 32,767
2801 Current, Lowest Phase Value A Amps/Scale 0 to 32,767
2802 Voltage, L-L, Highest Value D Volts/Scale 0 to 32,767
2803 Voltage, L-L, Lowest Value D Volts/Scale 0 to 32,767
2804 Voltage, L-N, Highest Value D Volts/Scale 0 to 32,767
2805 Voltage, L-N, Lowest Value D Volts/Scale 0 to 32,767
System Configuration
30003001
Circuit Monitor Label ——
30023009
Circuit Monitor Nameplate ——
3014 Circuit Monitor Present Operating System Firmware Version ——0x0000 to 0xFFFF
30343037 Present Date/Time See Template See Template
3039-3042 Last Unit Restart Date/Time See Template See Template
Table A3:Abbreviated Register List
Register
Number
Description
Scale
Factor
Units Register Range
See How Power Factor is Stored in the Registeron page 128.
The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value
between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to0; -0.999 maps to 0.999;0.999 leadingmaps to 1.001; and 0 leading
maps to 2. The alternate PF is also stored with a scale factor 0.001.
These configuration registers require that you enter the setup mode to change the registers contents. Issue command 9020 to enter setup
mode and 9021 to exit setup mode. See Using the Command Interface to Change Configuration Registerson page 187 for instructions on
howtousethesetup-modecommands.
Quantity available for 4-wire system only. Value set to -32,768 if not available.