Texas Instruments TMS320C67X/C67X+ DSP Car Speaker User Manual


 
Load Byte From Memory With a 5-Bit Unsigned Constant Offset or Register Offset LDB(U)
3-123 Instruction SetSPRU733
Load Byte From Memory With a 5-Bit Unsigned Constant Offset or
Register Offset
LDB(U)
Syntax Register Offset
LDB (.unit) *+baseR[offsetR], dst
or
LDBU (.unit) *+baseR[offsetR], dst
Unsigned Constant Offset
LDB (.unit) *+baseR[ucst5], dst
or
LDBU (.unit) *+baseR[ucst5], dst
.unit = .D1 or .D2
Compatibility C62x, C64x, C67x, and C67x+ CPU
Opcode
31 29 28 27 23 22 18 17 13 12 9 8 7 6 4 3 2 1 0
creg z dst baseR offsetR/ucst5 mode 0 y op 0 1 s p
3 1 5 5 5 4 1 3 1 1
Description Loads a byte from memory to a general-purpose register (dst). Table 317
summarizes the data types supported by loads. Table 311 (page 3-33)
describes the addressing generator options. The memory address is formed
from a base address register (baseR) and an optional offset that is either a
register (offsetR) or a 5-bit unsigned constant (ucst5). If an offset is not given,
the assembler assigns an offset of zero.
offsetR and baseR must be in the same register file and on the same side as
the .D unit used. The y bit in the opcode determines the .D unit and register
file used: y = 0 selects the .D1 unit and baseR and offsetR from the A register
file, and y = 1 selects the .D2 unit and baseR and offsetR from the B register
file.
offsetR/ucst5 is scaled by a left-shift of 0 bits. After scaling, offsetR/ucst5 is
added to or subtracted from baseR. For the preincrement, predecrement, pos-
itive offset, and negative offset address generator options, the result of the
calculation is the address to be accessed in memory. For postincrement or
postdecrement addressing, the value of baseR before the addition or subtrac-
tion is the address to be accessed in memory.
Table 317. Data Types Supported by LDB(U) Instruction
Mnemonic
op
Field
Load Data Type SIze
Left Shift of
Offset
LDB 0 1 0 Load byte 8 0 bits
LDBU 0 0 1 Load byte unsigned 8 0 bits