Functional Unit Constraints
4-51PipelineSPRU733
Table 4−35 shows the instruction constraints for ADDDP/SUBDP instructions
executing on the .L unit.
Table 4−35. ADDDP/SUBDP .L-Unit Instruction Constraints
Instruction Execution
Cycle 1 2 3 4 5 6 7 8
ADDDP/SUBDP R R W W
Instruction Type
Subsequent Same-Unit Instruction Executable
Single-cycle Xr Xw Xw
4-cycle Xr Xw Xw
INTDP
Xrw Xw Xw
ADDDP/SUBDP
Xr
Instruction Type
Same Side, Different Unit, Both Using Cross Path Executable
Single-cycle Xr
DP compare Xr
2-cycle DP
Xr
4-cycle
Xr
Load
Store
Branch
Xr
16 × 16 multiply
Xr
MPYI
Xr
MPYID
Xr
MPYDP
Xr
Legend: = E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the
instruction;
= Next instruction can enter E1 during cycle; Xr = Next instruction cannot enter E1 during cycle-read/
decode constraint; Xw = Next instruction cannot enter E1 during cycle−write constraint; Xrw = Next instruction cannot
enter E1 during cycle−read/decode/write constraint